General
Equipment Area Dimensions3,430 × 1,410 × 2,000 mm
Transport Dimensions (Growing Unit)2,820 × 1,480 × 2,100 mm
Transport Dimensions (Control Unit)1,480 × 830 × 2,100 mm
Door Outswing614 mm
Growing Area2,440 × 1,220 mm × 4 tiers
Growing Layers1 / 2 / 3 / 4 (configurable)
Per-Layer Growing Height (4-layer)462 mm / 259 mm below LED
Total Equipment WeightApprox. 800 kg
CertificationCE
Electrical
Input Power (Peak)4,240 W
Input Voltage220–240 V
Input Current20 A
Frequency50 Hz
Total Cooling Capacity5.5 kW
Compressor COP2.99 (Panasonic 5KS170FBB21)
Heating Power1 kW (PTC, 3% efficiency)
Nutrient Pump Power0.37 kW
Lighting — Per Layer
Leafy Greens / Nursery400 W per layer
Strawberries / Flowers500 W per layer
Tomatoes / Woody Plants1,300 W per layer
Spectral ProgrammesWhite · UV · Blue · Deep Red · Far Red
Key Wavelengths385 / 450 / 400–700 / 660 / 730 nm
Temperature & Climate
Operating Environment Range0°C – 30°C
Internal Temp Control @ 25°C10°C – 28°C
Humidity Control Range @ 25°C45% – 99%
Humidification Capacity134 litres / day
CO₂ Control Range400 – 3,000 PPM
Air Circulation in Growing Area30 times / hour
Photon Hydrogen Ion Density10¹¹ per m²
Water & Nutrient Control
Water Tank Capacity150 litres
Adjustable Water Temperature10°C – 23°C
Internal Air Exchange2 times / minute
Nutrient Solution Channels4
Peristaltic Pump Flow Rate100 ml / min
Oxygenation MethodVenturi (optional nano bubble stone)
Growth-Stage ProgrammesUp to 16 per cultivation pack
Configurable ParametersUp to 1,000 per pack
Sterilisation
Air Sterilisation Rate50 times / hour
Pathogen EliminationUp to 95% (bacteria & viruses)
Photohydrogen Density10¹¹ / m³
Water SterilisationUV light — reservoir
ScopeAir + water simultaneous
Digital & Connectivity
Edge ServerAgriculture Processing Unit (APU)
Communication ProtocolRS485 + TCP/IP
Remote AccessWeb · iOS · Android · On-site panel
Max Units Managed10,000+
User AccountsMulti-account, multi-level permissions
API AccessCloud integration for AI model training